RTDs / Surface RTDs : STIKON® Immersible

RdF STIKON® Immersible Platinum RTDs

29272, 29280


Sensors 29272 and 29280 are completely immersible in aggressive chemicals at high temperatures. May be surface mounted and submerged. For tight temperature control, this low cost versatile platinum RTD features 0.05°C stability and small size.

Available in 100 or 1000 ohm configurations with two, three or four wire flat cable, Model 29280 fits through a 1.4mm (0.055 inch) gap for maximum accessibility up to 260°C (500°F).

Model 29272 with tough, round cable leads and lower cost is useful in temperatures up to 232 °C(450°F).

  • High Temperature Flat Design

  • Fits Narrow Accesses

  • Platinum RTD Stability

  • Custom Lead Length

  • Universal Configuration is also surface mountable

  • PFA Sensor for Maximum Temperature & Chemical Resistance.


Performance Specifications

   
 

Temperature Range
29272: -200°C to 232°C(-320°F to 450°F)
29280: -200°C to 260°C(-320°F to 500°F)

Sensing Element
International grade thin film platinum, α=0.00385 Ω/Ω/°C or
Industrial grade thin film platinum, α = 0.00375 Ω/Ω/°C

Ice Point Resistance
100 ± 0.12 Ω or 1000 ± 1.2 Ω,
IEC 751 Class B, (±0.12%)

Time Constant
<0.3 Seconds on metal surfaces

Self-Heating
>25 mW/°C immersed

Interchangeability
±(0.3°C @ 0°C + 0.005 |t|°C)
IEC 751 Class B above –50°C

Long Term Stability
Better than 0.05°C (0.02Ω)
per 5 years, above –50°C

Insulation Resistance
>50 MegOhms at 50 VDC at 25°C

 

Maximum Current
100Ω = 5 mA, 1000Ω = 2 mA
for limited seIf heating

Recommended Current
1 mA

Case Material
Kapton®

Lead Material
Stranded copper cable insulated as follows:
29272: 22 AWG tin-plated, (2-wire) FEP Teflon® over each twisted black/red, FEP overall.
24 AWG tin-plated, (3-wire) FEP Teflon® over each
twisted white/2 red, FEP overall
29280: 26 AWG nickel-plated, PFA Teflon®, 2 white, 2 white/brown, or 2 white/2 red fused parallel

Sizes
29272: 0.3" wide x 0.8" long x 0.05" thick, 0.11" diameter cable
29280: 0.25" or 0.30"(4-wire) wide x 0.5" long x 0.05" thick, 0.04" thick flat cable

   

Teflon® and Kapton® are registered trademarks of Dupont



Dimensional Drawing


Ordering Specifications

   29272   RTD with FEP sensor and lead cable encapsulation
   29280   RTD with PFA sensor and lead encapsulation
 
   RTD RESISTANCE SPECIFICATION (ohms @ O°C)
   T01 100W ±0.12Ω @ 0°C, 0.06"x0.1 sensor   (α= 0.00385 Ω/Ω/°C International Grade IEC 751 Class B)
   T10 1000Ω ±1.2W @ 0°C, 0.08"x0.13 sensor  (α = 0.00385 Ω/Ω/°C International Grade IEC 751 Class B)
 
      NUMBER OF LEADS:
      A      2 wire Ribbon Cable
      B      3 wire Ribbon Cable
      C      4 wire Ribbon Cable (29280 only)
      D      2 wire, PFA Ins Twisted with PFA Jacket (29280 only)
      E      3 wire PFA Ins Twisted with PFA Jacket (29280 only)
      F      4 wire PFA Ins Twisted with PFA Jacket (29280 only)
 
   LEAD LENGTH in inches (12 inches standard)
29272
T10
A
72
 Typical write-up for 29272
29280
T01
C
12