RTDs / Surface RTDs : STRAPON® Wide Range

RdF STRAPON® Wide Range Surface RTD

PNs 22391, 22392, 22393


  • Platinum Surface RTD with wide temperature range

  • Non-penetrating design with hardware options for easy installation

  • Sensor sealed for condensing or wet environments

  • Stable: drift is less than ±0.05°C over 5 years

  • Permanently bonded assemblies with metal contact plate under sensor and high-performance bonded fiber insulation over sensor

  • Mount by bonding (22391), bolt(22392) or strap (22393)


Performance Specifications

   
 

Wide Operating Temperature Range
–200°C to +232°C (–320°F to +450°F)
continuous as mounted.
260°C (500°F) short term clamped.

Sensing Element
International grade thin film platinum α= 0.00385 Ω/Ω/°C or
Industrial grade thin film platinum α = 0.00375 Ω/Ω/°C

Ice Point Resistance
100±0.12Ω or 1000±1.2Ω;
Class B (±0.12%)

Interchangeability
±0.3°C or 0.6% of temperature IEC 751
Class B above –50°C

Long Term Stability
Less than 0.05°C drift per 5 years above –50°C

Time Constant
Less than 1/2 second for the sensor
to reach 63.2% of a change in temperature

Self-Heating
The bare sensor will rise less than 1°C
while dissipating 25 milliwatts mounted.

     

Insulation Resistance
The insulation resistance between outer sensor insulation
clamped between two metal plates and the common leadwire is:
50 megohms minimum with 50 Volts DC applied.

Maximum Current
100Ω=5mA, 1000Ω=2mA
for limited self heating

Recommended Current
1mA

Body Material
Stainless Steel and flexible
polyimide fiber insulation

Lead Material
Stranded copper cable
insulated as follows:
22 AWG tin-plated, (2-wire) FEP Teflon® over each twisted
black/red, FEP overall. 24 AWG tin-plated, (3-wire) FEP Teflon® over each twisted
white/2 red, FEP overall 26 AWG nickel-plated, PFA Teflon®, 2 white, 2 white/brown,
or 2 white/2 red fused parallel

   

Teflon® and Kapton® are registered trademarks of Dupont


Dimensional Drawing


Ordering Specifications

  22391   Strapon® for adhesive or tape mounting
  22392   Strapon® for bolt down with 3/16, #8 or 4.5mm
  22393   Strapon® for curved surface >2" dia. with pipe clamp, can bolt down
 
    Resistance Specification @ 0°C
    T01    100Ω ± 0.12Ω@ 0°C, (α = 0.00385Ω/Ω/°C)Thin Film (IEC 751)
    T10    1000Ω ± 1.2Ω@ 0°C, (α = 0.00385Ω/Ω/°C) Thin Film (IEC 751))
    H10    1000Ω ± 1.2Ω@ 0°C, (α =0.00375Ω/Ω/°C) Thin Film (Industrial)
 
      Number of Leads:
      A       2 wire
      B       3 wire
      C       4 wire
 
    Lead Length in inches (12 inches standard)
 
   Pipe Clamp – 22393 Only
0
1
2
3
4
5
No Clamp
Pipe Dia. 2" to 8 (54825-1)
Pipe Dia. 8" to 10" (54825-2)
Pipe Dia. 10" to 16" (54825-3)
Pipe Dia. 16" to 24" (54825-4)
Pipe Dia. 24" to 34" (54825-5)
22391
-
T01
-
B
-
12
-
- Typical write-up for 22391

Installation Note

These Strapon® sensors are manufactured with the sensor attached to a contact shim and then overmolded with an insulating layer ready to be clamped to the surface.

When installing a Strapon® style sensor, the sensor should be tightened until the shim is firmly on the surface, but not tight enough to strain the sensing element or deform the silicone rubber. A thermal grease can be used between the surface and sensing shim to increase the thermal conductivity if desired, but it should be noted that some silicone heat sink compounds could have an adverse effect on the silicone overmold.

Strapon® Models 22393 and 26393 have an adapter and pipe clamp to facilitate installation. The adapter has a built-in stop to prevent excessive tightening of the clamp.